8KVA to 20KVA, 180pcs 2V battery over voltage protection Single Phase Online UPS
UPS system MP31-8KVA to 20KVA:
Model |
MP 3106K |
MP 3110K |
MP 3115K |
MP 3120K |
MP 3130K |
MP 3140K |
MP 3160K |
MP 3180K |
|
Work principle |
Pure sine wave on line |
||||||||
Phase |
3phase+N+G |
||||||||
Input power factor |
>0.8 |
||||||||
Rectifier |
Nominal input voltage |
220/380VAC; 230/400VAC; 240/415VAC |
|||||||
Range |
±25% |
||||||||
Nominal input frequency |
50Hz/ 60Hz±10% |
||||||||
Output ripple |
2 |
||||||||
Soft start |
0-100% 5sec |
||||||||
Float Voltage |
405VDC |
||||||||
Boost Voltage |
415VDC |
||||||||
Temperature compensation voltage |
3mv/(monomer) |
||||||||
Charge current |
MAX 30A |
||||||||
Battery |
Battery Type |
maintenance-free lead acid battery |
|||||||
Battery number |
30pcs 12V, or 180pcs 2VNominal voltage 360VDC |
||||||||
Inverter |
Phase |
Single L+N+G |
|||||||
Rated power |
Rated capacity ×0.8 |
||||||||
Nominal voltage |
220/380VAC; 230/400VAC; 240/415VAC |
||||||||
Output voltage stability |
±1%( Stable load); ±3%( fluctuant load) |
||||||||
Output frequency stability |
50Hz/60Hz±0. 5% |
||||||||
Crest factor |
> 3:1 |
||||||||
Output waveform distortion |
Sine wave , linear load<3%;non-linear load<5% |
||||||||
Dynamic characteristics |
Instant voltage<±5%(from 0 to100% ), Instant recover time<10mS |
||||||||
Unbalanced load voltage |
±5% |
||||||||
Overload Protection |
125%10 S; 125%1S;150% 10 ms |
||||||||
Efficiency |
>93% full load |
||||||||
Bypass |
Phase |
Single L+N |
|||||||
Nominal voltage |
220/380VAC; 230/400VAC; 240/415VAC |
||||||||
Transfer time |
<1mS( static switch with 0 transfer time ) |
||||||||
Protection |
Input protection |
Input voltage/frequency over limited ;wrong phase; lack phase protection |
|||||||
Output protection |
Over current; short circuit ; factor low protection |
||||||||
Battery protection |
Over charge ; over-discharge protection |
||||||||
Temperature protection |
Environment over temperature protection; inverter over temperature protection |
||||||||
Communication Interface |
RS232, RS485; optional SNMP card(for internet long distance monitor ) |
||||||||
Redundancy function |
Tandem hot backup or parallel connection |
||||||||
Anti-surge capacity |
10/700μS, 5KV 8/20μS, 20KA |
||||||||
Protection level |
Ip31 |
||||||||
Safety performance |
Vin-n Vout-n 3000Vac, creepage<3.5mA , insulating resistance>2MΩ(500VDC) |
||||||||
Noise (dB) |
45~50 |
50~55 |
55~58 |
55~60 |
|||||
Dimension W×D×Hmm |
430×750×1050 |
430×765×1050 |
430×765×1080 |
980×800×1800 |
|||||
Weight(Kg) |
70 |
135 |
158 |
185 |
215 |
318 |
445 |
498 |