Add to Cart
4KVA - 10KVA, 220VAC, ECO mode overload protection Single Phase Online UPS
UPS MP11-4KVA to 10KVA:
1. EPS mode, UPS mode, ECO mode
2. Adopt the 6th generation IGBT and 4 layer PCB
3. LCD display
UPS MP11-4KVA to 10KVA:
1. Pure sine wave output, true on-line dual conversion design
2. Adopt 4 layer PCB, and SMD technology.
3. The sixth generation IGBT, the inverter has high efficiency, low temperature, high reliability.
4. Touch screen display, with the simple operation and Intuitive data, optional display language and logo.
5. Set the work mode on the display directly, UPS mode, ECO mode, EPS mode.
6. Intelligent detecting function
7. Excellent load feature, it is completely capable to load from 0-100% while no need to change to bypass
8. Cold start
9. Generator compatible
10. RS232 and RS485 standard collocation, optional SNMP and dry contact
11. Perfect protection.
12. Selectable battery inspection module
13. High-powered dynamic feature
14. Optional input harmonic filter
Model |
MP 1101K |
MP 1102K |
MP 1103K |
MP 1104K |
MP 1106K |
MP 1108K |
MP 1110K |
MP 1115K |
MP 1120K |
||||||||
Working WAVE |
Pure sine wave on line |
||||||||||||||||
Phase |
1phase+N+G |
||||||||||||||||
Input Power factor |
>0.85 |
||||||||||||||||
Rectifier |
Input voltage |
220Vac; 230Vac; 240Vac |
|||||||||||||||
Range |
±25% |
||||||||||||||||
Input frequency |
50Hz±10%;60Hz±10%; |
||||||||||||||||
Input THD |
<2% |
||||||||||||||||
Soft startup |
0~100% 5sec |
||||||||||||||||
Charge |
Charge mode |
constant current to constant voltage, with temp compensation; with Auto change |
|||||||||||||||
Float voltage |
55VDC |
220VDC |
|||||||||||||||
Temp. compensation |
3mV/ 1 pcs |
||||||||||||||||
Charge current |
5Amp-20Amp |
||||||||||||||||
Battery |
Battery type |
maintenance-free lead acid battery |
|||||||||||||||
Battery capacity |
7~999AH settable (according to the capacity) |
||||||||||||||||
Battery number |
4pcs 12V |
16pcs 12V |
|||||||||||||||
Inverter |
Phase |
1 phase |
|||||||||||||||
Rated capacity |
Rated capacity ×0.8 |
||||||||||||||||
Output Voltage |
220Vac; 230Vac; 240Vac |
||||||||||||||||
Output voltage distortion |
±1 %( Stable load); ±5%( fluctuant load) |
||||||||||||||||
Freq distortion |
50Hz 60Hz<±0.5% |
||||||||||||||||
crest factor |
>3:1 |
||||||||||||||||
Output THD |
Sine wave , linear load<3%;non-linear load<5% |
||||||||||||||||
Dynamic characteristic |
Instant voltage<±5%(from 0 to100% ), Instant recover time<10MP11 |
||||||||||||||||
Imbalance load voltage |
Output Voltage <±5% |
||||||||||||||||
Overload protection |
150% 1min; 200% 1S |
||||||||||||||||
Efficiency |
>93%(full load) |
||||||||||||||||
Bypass |
phase |
Single phase+N |
|||||||||||||||
Voltage |
220Vac; 230Vac; 240Vac |
||||||||||||||||
Transfer time |
<1MP11( static switch with 0 S ) |
||||||||||||||||
Protection |
Input protection |
Input over/low voltage ;over frequency |
|||||||||||||||
Output protection |
Over current short circuit ; factor low |
||||||||||||||||
Battery protection |
Over charge ; over-discharge |
||||||||||||||||
Temp protection |
Environment over temp protection, inverter over temp protection |
||||||||||||||||
Hardware failure |
Assistant power abnormal, breaker cut off, breaker overload, power components over current/over voltage etc protection |
||||||||||||||||
Cooling |
COMPULSIVE VENTILATION(with temperature control) |
||||||||||||||||
communication |
RS232/ RS485; optional SNMP card(for internet) |
||||||||||||||||
Safety rate |
IP21 |
||||||||||||||||
Noise (dB) |
45~60 |
||||||||||||||||
Size (W*D*H) |
210*452*510 |
220*578*540 |
380*900*680 |
430*750*1050 |
|||||||||||||
Weight(Kg) |
35 |
58 |
65 |
82 |
105 |
200 |
245 |
265 |
300 |